Loading...
HomeMy WebLinkAbout2026.02.05 Item 6a Attachment - Project PlansN T-1 1 TITLE SHEET NTS LOCATION MAP PROJECT SITE VICINITY MAP N.T.S. DIRECTORS: NICK EXLINE NICK HAVEN JOEL HENDERSON SHANE ROMSOS KELLY SHEEHAN GENERAL MANAGER: PAUL HUGHES N SITE LOCATION APPROVED FOR PURPOSES OF GOVERNMENT CODE 830.6 : N BOARD OF DIRECTORS SOUTH TAHOE PUBLIC UTILITY DISTRICT AGENCY & UTILITY CONTACTS SOUTH TAHOE PUBLIC UTILITY DISTRICT 2026 STATELINE TANKS RECOATING PROJECT SHEET DRAWING DESCRIPTION 1 T-1 TITLE SHEET 2 G-1 ABBREVIATIONS, LEGEND AND GENERAL NOTES 3 C-1 PLAN 4 D-1 SITE PHOTOS 5 D-2 EXT LADDER PHOTOS 6 SD-1 STANDARD DETAILS 7 CP-1 TANK #1 CATHODIC PROTECTION (PLAN AND SECTIONS) 8 CP-2 TANK #1 CATHODIC PROTECTION (DETAILS 1) LA K E P A R K W A Y STATELINE TANKS ACCESS ROAD HE A V E N L Y VIL L A G E W A Y STATELINE TANK NO. 2 (2.25 MG)STATELINE TANK NO. 1 (1.25 MG) SOUTH TAHOE PUBLIC UTILITY DISTRICT 1275 MEADOW CREST DRIVE SOUTH LAKE TAHOE, CALIFORNIA 96150 PHONE (530) 544-6474 FAX (530) 541-4319 WWW.STPUD.US OF SHEETS PROJECT CODE REVISIONDATEBY APPROVED DATE SCALE DATE DESIGNED BY DRAWN BY AS-BUILT DRAWN BY AS-BUILT DATE 122026 STATELINE TANKS RECOATING PROJECT SLTNK1/SLTNK2 FEBRUARY 2026 TJ/BG TJ LIST OF DRAWINGS 1/28/2026 9 CP-3 TANK #1 CATHODIC PROTECTION (DETAILS 2) 10 CP-4 TANK #2 CATHODIC PROTECTION (PLAN AND PROFILE) 11 CP-5 TANK #2 CATHODIC PROTECTION (DETAILS 1) 12 CP-6 TANK #2 CATHODIC PROTECTION (DETAILS 2) LIST OF DRAWINGS CONTINUED SHEET DRAWING DESCRIPTION G-1 2 ABBREVIATIONS, LEGEND AND GENERAL NOTES N/A SOUTH TAHOE PUBLIC UTILITY DISTRICT 1275 MEADOW CREST DRIVE SOUTH LAKE TAHOE, CALIFORNIA 96150 PHONE (530) 544-6474 FAX (530) 541-4319 WWW.STPUD.US OF SHEETS PROJECT CODE REVISIONDATEBY APPROVED DATE SCALE DATE DESIGNED BY DRAWN BY AS-BUILT DRAWN BY AS-BUILT DATE 122026 STATELINE TANKS RECOATING PROJECT SLTNK1/SLTNK2 FEBRUARY 2026 TJ/BG TJ ABND ABANDONED BLDG.BUILDING CENTERLINE C&G CURB AND GUTTER CB CATCH BASIN CPLG COUPLING CSLT CITY OF SOUTH LAKE TAHOE DI DRAINAGE INLET DIA DIAMETER DIP DUCTILE IRON PIPE DWY DRIVE WAY (E) EXISTING EXT EXTERIOR ELEV ELEVATION (F)FUTURE FG FINISHED GRADE FH FIRE HYDRANT FI FLUSH INLET FL FLOW LINE FLG FLANGE FM FORCE MAIN FS FINISHED SURFACE GV GATE VALVE ID INSIDE DIAMETER INT INTERIOR INV INVERT JT JOINT L LENGTH LF LINEAR FEET LOC LOCATION MAX MAXIMUM MG MILLION GALLONS MH MANHOLE MIN MINIMUM MJ MECHANICAL JOINT MON MONUMENT NC NORMALLY CLOSED OC ON CENTER OD OUTSIDE DIAMETER OHU OVERHEAD UTILITY (P) PROPOSED ⅊PROPERTY LINE PCC PORTLAND CEMENT CONCRETE PP POWER POLE PRV PRESSURE RELEASE VALVE PTW PIPE TRACER WIRE PVC POLYVINYL CHLORIDE R/W RIGHT-OF-WAY RCP REINFORCED CONCRETE PIPE REQ'D REQUIRED RJ RESTRAINED JOINT RMVD REMOVED SCH SCHEDULE SD STORM DRAIN SDMH STORM DRAIN MANHOLE SEZ STREAM ENVIRONMENT ZONE SPEC SPECIFICATIONS SS SANITARY SEWER, STAINLESS STEEL SSMH SANITARY SEWER MANHOLE STA STATION STD STANDARD STL STEEL STPUD SOUTH TAHOE PUBLIC UTILITY DISTRICT TEMP TEMPORARY TG TOP OF GRATE TRPA TAHOE REGIONAL PLANNING AGENCY TYP TYPICAL UG UNDERGROUND UNK UNKNOWN USFS UNITED STATES FOREST SERVICE VAR VARIES WM WATER METER WV WATER VALVE ABBREVIATIONS 1.THE FOLLOWING GENERAL NOTES ARE GENERAL AND APPLY TO ALL SHEETS OF THEIR CONTRACT DOCUMENTS AS IF THEY WERE WRITTEN IN THEIR ENTIRETY ON EACH SHEET. 2.CONTRACTOR SHALL HAVE SIGNED PLANS, SPECIFICATION AND PERMITS IN THEIR POSSESSION PRIOR TO COMMENCEMENT OF WORK. 3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING ALL UTILITY COMPANIES, LOCAL AGENCIES AND/OR UTILITY DISTRICTS AS TO THE LOCATION OF ALL UNDERGROUND FACILITIES. LOCATION AND DEPTH OF EXISTING UTILITIES WHERE SHOWN ON PLANS ARE BASED ON AVAILABLE RECORDS OR ELECTRONIC FILES INFORMATION. NEITHER THE OWNER NOT THE ENGINEER ASSUMES ANY RESPONSIBILITY FOR FACILITIES AND UTILITIES NOT SHOWN OR NOT IN THE LOCATION SHOWN. NO GUARANTEE IS MADE AS TO THE ACCURACY OF THIS INFORMATION OR THAT ALL UTILITIES ARE SHOWN. THE CONTRACTOR SHALL FIELD VERIFY ALL LOCATIONS, SIZES, MATERIAL TYPES, AND ELEVATIONS SHOWN AROUND OR NEAR AREAS OF NEW CONSTRUCTION PRIOR TO START OF CONSTRUCTION. IT SHALL BE THE CONTRACTORS SOLE RESPONSIBILITY TO LOCATE, PROTECT, AND MAINTAIN ALL EXISTING UTILITIES. THE CONTRACTOR OR ANY SUBCONTRACTOR FOR THIS CONTRACTOR SHALL NOTIFY MEMBERS OF UNDERGROUND SERVICE ALERT 48 HOURS IN ADVANCE OF PERFORMING EXCAVATION WORK BY CALLING UNDERGROUND SERVICE ALERT 811. EXCAVATION IS DEFINED AS BEING 18 OR MORE INCHES OF DEPTH BELOW THE EXISTING SURFACE. 4.CONTRACTOR TO BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING MONUMENTS AND ANY OTHER SURVEY MARKERS DURING CONSTRUCTION. ALL SUCH MONUMENTS OR MARKERS DISTURBED OR DESTROYED DURING CONSTRUCTION SHALL BE REPLACED BY A CALIFORNIA LICENSED SURVEYOR AT CONTRACTOR'S EXPENSE. 5.PRIOR TO CONSTRUCTION ACTIVITY THE CONTRACTOR SHALL SUBMIT TO THE DISTRICT FOR ACCEPTANCE A PROJECT SPECIFIC TRAFFIC CONTROL PLAN FOR HANDLING TRAFFIC THROUGH THE PROJECT SITE. ALL TRAFIC CONTROL MEASURES SHALL MEET OR EXCEED THE REQUIREMENTS OUTLINED IN THE STATE OF CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (2014), ALL ADVANCE WARNING SIGNS SHALL BE A 48" BY 48" MINIMUM. A FLAGGER SHALL BE LOCATED FAR ENOUGH IN ADVANCE OF THE WORK AREA AS TO SLOW OR STOP TRAFFIC THROUGH THE WORK AREA. ALL PORTABLE DELINEATORS SHALL BE PLACED A MAXIMUM OF 20 FEET APART. 6.UNLESS DETAILED, SPECIFIED, OR OTHERWISE INDICATED ON THE DRAWINGS, CONSTRUCTION SHALL BE AS INDICATED IN THE APPLICABLE TYPICAL DETAILS AND GENERAL NOTES. TYPICAL DETAILS SHALL APPLY EVEN THOUGH NOT REFERENCED AT SPECIFIC LOCATIONS ON THE DRAWINGS. 7.WHERE NO CONSTRUCTION DETAILS ARE SHOWN OR NOTED FOR ANY PART OF WORK, DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. 8.THE CONTRACTOR SHALL TAKE ALL PRECAUTIONARY MEASURES NECESSARY TO PROTECT FROM DAMAGING EXISTING FACILITIES AND UTILITIES SHOWN OR NOT SHOWN THAT ARE TO REMAIN IN PLACE. ALL FACILITIES DAMAGED BY THE CONTRACTOR'S OPERATIONS SHALL BE EXPEDITIOUSLY REPAIRED OR RECONSTRUCTED TO THE ORIGINAL OR BETTER CONDITION AT THE CONTRACTOR'S EXPENSE WITHOUT ADDITIONAL COMPENSATION. 9.UNLESS OTHERWISE INDICATED IN THE DRAWINGS AND SPECIFICATIONS, THE CONTRACTOR SHALL ABIDE BY THE FOLLOWING TRAFFIC CONDITIONS. CONTRACTOR SHALL MAINTAIN THE CONTINUOUS FLOW OF TRAFFIC AT ALL TIMES DURING CONSTRUCTION ACTIVITY. AFTER WORKING HOURS ALL TRAFFIC BARRIERS SHALL BE REMOVED AND TRAFFIC RETURNED TO NORMAL. 10.CONTRACTOR SHALL REMOVE ALL MATERIAL GENERATED BY ANY ASPHALT SAW CUTTING OPERATION DURING OR IMMEDIATELY AFTER SAWCUTTING BY USING ADEQUATELY SIZED VACUUMING EQUIPMENT TO ACCOMMODATE THE REMOVAL PROCESS. 11.CONTRACTORS EQUIPMENT AND EMPLOYEE VEHICLES SHALL PARK ON EXISTING PAVED SURFACES OR EXISTING COMPACTED ROAD SHOULDERS. NO PARKING OFF PAVED SURFACES WHEN COVERED WITH SNOW OR MUDDY CONDITIONS EXIST. NO EQUIPMENT OR VEHICLES SHALL BE PLACED OUTSIDE THE STATE, CITY, OR COUNTY RIGHT OF WAY. ANY DISTURBANCE OF PRIVATE PROPERTY SHALL BE RESTORED BY THE CONTRACTOR AT THEIR EXPENSE. 12.ALL SEWER PIPES DAMAGED DURING THE EXECUTION OF THE PROJECT SHALL BE REPAIRED PER DETAILS. 13.CONTRACTOR SHALL EXPECT SHALLOW GROUNDWATER TO BE ENCOUNTERED WITHIN 5 FEET BELOW GROUND SURFACE IN SEZ AREAS, AS DEPICTED ON SHEET INDEX MAP (SHT G1). DEWATERING PER SPECIFICATIONS REQUIRED. 14.WORK SHALL BE IN CONFORMANCE WITH THE ENCROACHMENT PERMIT ISSUED BY THE CITY OF SOUTH LAKE TAHOE. NO WORK SHALL OCCUR ON SATURDAYS OR SUNDAYS OR HOLIDAYS WITHOUT WRITTEN PERMISSION FROM THE DISTRICT AND THE CITY OF SOUTH LAKE TAHOE. 15.ALL EXCAVATIONS SHALL BE BACKFILLED OR TRENCH PLATED AT THE END OF EACH DAY'S WORK PER THE SPECIFICATIONS. EXCAVATIONS WITHIN EXISTING PAVED AREAS SHALL BE HOT PATCHED AS REQUIRED PER SPECIFICATIONS TO MATCH THE EXISTING PAVEMENT AT THE END OF EACH DAY'S WORK. ALL TRENCH PLATES SHALL BE NON-SKID TYPE AND HAVE COLD PATCH APPLIED TO THE EDGE FOR TRAFFIC APPROACH AND DEPARTURE. 16.ALL SIGNAGE REMOVED OR DAMAGED SHALL BE REPLACED TO CURRENT STANDARDS. 17.THE CONTRACTOR SHALL TAKE SPECIAL PRECAUTIONS IN THE VICINITY OF ANY OVERHEAD ELECTRICAL LINES. CONTRACTOR SHALL ABIDE BY THE NATIONAL ELECTRIC CODE AND ANY REQUIREMENT BY THE OWNER OF THE ELECTRIC LINES. 18.THE CONTRACTOR SHALL PROVIDE ALL SHEETING AND SHORING REQUIRED TO PROTECT EXISTING STRUCTURES, PIPES, AND FACILITIES. 19.A MINIMUM HORIZONTAL SEPARATION OF 10 FEET SHALL BE MAINTAINED BETWEEN WATER MAINS AND SANITARY SEWER. WHERE WATER MAINS MUST CROSS SANITARY SEWER, NO PIPE JOINTS SHALL BE PLACED WITHIN 10 FEET OF THAT CROSSING.WHERE IT IS IMPRACTICAL TO MAINTAIN THE MINIMUM CLEARANCE, WRITTEN DIRECTION WILL BE PROVIDED BY THE DISTRICT ENGINEER. 20.MAINTAIN 1' VERTICAL CLEARANCE FROM ALL GAS MAINS. GENERAL NOTES BMP GENERAL NOTES 1.ON-SITE WORK SHALL BE PERFORMED FROM 8 AM TO 6 PM, MONDAY THROUGH FRIDAY. WORK OUTSIDE THESE HOURS MUST BE APPROVED BY THE DISTRICT A MINIMUM OF 48-HOURS BEFORE THE ABNORMAL WORKING HOURS ARE SCHEDULED TO BEGIN. 2.THE CONTRACTOR SHALL COMPLY WITH THE TAHOE REGIONAL PLANNING AGENCY (TRPA) STANDARD CONDITIONS OF APPROVAL (ATTACHMENT Q). A PRE-GRADE INSPECTION SHALL BE COMPLETED PRIOR TO ANY SAWCUTTING OR EXCAVATION ACTIVITIES. 3.THE CONTRACTOR SHALL COMPLY WITH THE STATE WATER QUALITY CONTROL BOARD WASTE DISCHARGE REQUIREMENTS FOR THIS PROJECT AND THE CITY OF SOUTH LAKE TAHOE'S OR THE EL DORADO COUNTY'S ENCROACHMENT PERMIT. 4.NOISE SHALL BE REDUCED BY MANDATORY USE OF MUFFLERS ON ALL CONSTRUCTION VEHICLES AND EQUIPMENT. WHERE FEASIBLE, SOLENOID PAVEMENT BREAKERS WILL BE USED IN LIEU OF AIR POWERED JACK HAMMERS. 5.NOISE GENERATING ACTIVITIES WILL BE LIMITED TO THE HOURS OF 8:00 AM TO 6:00 PM. 6.THE CONTRACTOR SHALL APPLY EITHER WATER OR DUST PALLIATIVE OR BOTH, AS REQUIRED AT THE OPTION OF THE OWNER OR HIS REPRESENTATIVE, FOR THE ALLEVIATION OR PREVENTION OF DUST NUISANCE. 7.CONTRACTOR SHALL PROVIDE A VACUUM SWEEPER TRUCK FOR CLEANING OF THE SITE DURING AND AFTER CONSTRUCTION EACH DAY AS REQUIRED TO PREVENT SEDIMENT RUN OFF AND TO AID IN DUST CONTROL. 8.CONTRACTOR SHALL PROVIDE CRUSHED ROCK IN AREAS OF TEMPORARY CONSTRUCTION ACCESS TO MINIMIZE MIGRATION OF SEDIMENT. 9.ALL DISTURBED AREAS SHALL BE RESTORED TO MATCH PRE-EXISTING CONDITIONS. UNIMPROVED AREAS AND AREAS NOT LANDSCAPED SHALL BE REVEGETATED WITH NATIVE SPECIES PER TRPA BEST MANAGEMENT PRACTICES (BMP). EXISTING VEGETATION REMOVED DURING CONSTRUCTION SHALL BE CHIPPED AND MULCHED ON SITE AND STORED FOR USE DURING REVEGETATION. 10.ALL TREES IN JEOPARDY OF DAMAGE BY CONSTRUCTION ACTIVITIES AS DETERMINED BY THE DISTRICT SHALL BE PROTECTED PER DETAIL 5 ON PAGE D4. 11.SOIL AND CONSTRUCTION MATERIAL SHALL NOT BE TRACKED OFF THE CONSTRUCTION SITE. GRADING OPERATIONS SHALL CEASE IN THE EVENT THAT DANGER OF VIOLATING THIS CONDITION EXISTS. 12.DURING CONSTRUCTION, ENVIRONMENTAL PROTECTION DEVICES, SUCH AS EROSION CONTROL, DUST CONTROL AND VEGETATION PROTECTION DEVICES SHALL BE MAINTAINED AT ALL TIMES. 13.LOOSE SOIL MOUNDS OR SURFACES SHALL BE PROTECTED FROM WIND OR WATER EROSION BY BEING APPROPRIATELY COVERED AT THE END OF EACH WORK DAY OR WHEN REQUIRED BY TRPA. 14.ALL EXCESS MATERIAL FROM THE PROJECT IS TO BE REMOVED FROM THE SITE AND DISPOSED OF AT A SITE APPROVED BY THE TAHOE REGIONAL PLANNING AGENCY. NO EXCESS MATERIAL SHALL BE STORED ON SITE AFTER HOURS. 15.EXCAVATED MATERIAL SHALL BE STORED UPGRADE FROM THE EXCAVATED AREA WHENEVER POSSIBLE. NO MATERIAL SHALL BE STORED IN ANY STREAM ENVIRONMENT ZONE (SEZ) OR WET AREA. 16.ONLY EQUIPMENT OF A SIZE AND TYPE THAT WILL DO THE LEAST AMOUNT OF DAMAGE, UNDER PREVAILING SITE CONDITIONS AND CONSIDERING THE NATURE OF THE WORK TO BE PERFORMED, WILL BE USED. 17.NO WASHING OF VEHICLES OR HEAVY EQUIPMENT, INCLUDING CEMENT MIXERS, SHALL BE PERMITTED ANYWHERE ON THE SUBJECT PROPERTY UNLESS AUTHORIZED BY TRPA IN WRITING. 18.NO VEHICLE OR HEAVY EQUIPMENT SHALL BE ALLOWED IN A STREAM ENVIRONMENT ZONE (SEZ) OR WET AREA EXCEPT AS AUTHORIZED BY TRPA. 19.THE CONTRACTOR SHALL PROTECT AND BE RESPONSIBLE FOR ANY DISTURBANCE OR CONTAMINATION TO ANY DRY WELLS, STORM WATER COLLECTION OR RETAINAGE SYSTEMS INCLUDING STORM DRAIN PIPE, CURB & GUTTER, VALLEY GUTTERS AND HORIZONTAL DRAINS THROUGH OUT THE PROJECT AREA. ANY DAMAGE SHALL BE REPAIRED AT NO ADDITIONAL COST TO DISTRICT. THE CONTRACTOR SHALL NOT STOCK PILE ANY MATERIAL UPON ANY DRAINAGE FACILITIES. 20.ALL CONSTRUCTION SHALL BE WINTERIZED BY OCTOBER 15 TO REDUCE THE WATER QUALITY IMPACTS ASSOCIATED WITH WINTER WEATHER AS FOLLOWS: A.FOR THE SITES THAT WILL BE INACTIVE BETWEEN OCTOBER 15 AND MAY 1: 1.1 TEMPORARY EROSION CONTROLS SHALL BE INSTALLED 1.2 TEMPORARY VEGETATION PROTECTION FENCING SHALL BE INSTALLED 1.3 DISTURBED AREAS SHALL BE STABILIZED 1.4 ONSITE CONSTRUCTION SLASH AND DEBRIS SHALL BE CLEANED UP AND REMOVED 1.5 WHERE FEASIBLE, MECHANICAL STABILIZATION AND DRAINAGE IMPROVEMENTS SHALL BE INSTALLED 1.6 SPOIL PILES SHALL BE REMOVED FROM THE SITE B.FOR THE SITES THAT WILL BE ACTIVE BETWEEN OCTOBER 15 AND MAY 1, IN ADDITION TO THE ABOVE REQUIREMENTS: 1.1 PERMANENT MECHANICAL EROSION CONTROL DEVICES SHALL BE INSTALLED, INCLUDING PAVING OF THE DRIVEWAYS AND PARKING AREAS. 1.2 PARKING OF VEHICLES AND STORAGE OF BUILDING MATERIALS SHALL BE RESTRICTED TO PAVED AREAS. 1.3 ALL WORK PERFORMED DURING THIS PERIOD MUST BE PERFORMED SO THAT THE PROJECT CAN BE WINTERIZED WITHIN 12 HOURS OF DIRECTION TO DO SO. GUARD POST ZONE LIMITS WATER SERVICE LINE SEWER MAIN WATER MAIN GAS ELECTRIC OIL STORM DRAIN RIGHT-OF-WAY EASEMENT RETAINING WALL TELEPHONE TELEVISION/CABLE FIBER OPTIC RECLAIMED WATER OVERHEAD UTILITY PROPOSED WATER MAIN VALVE WATER METER FIRE HYDRANT SEWER CLEAN OUT GAS VALVE EXISTING PULL BOX STORM DRAIN INLET SIGN TREE LIGHT POLE COUPLING SURVEY MONUMENT MANHOLE REDUCER PRESSURE RELEASE VALVE LEGEND POWER POLE GAS SIGN TRAFFIC LIGHT ANTENNA GUY WIRE MAILBOX EDGE OF PAVEMENT/ROAD CURB CONTOUR LINE (MAJOR) CONTOUR LINE (MINOR) STAGING AREA BOUNDARY WATER TANK GENERAL NOTES 1.PRIOR TO PLACING THE WATER STORAGE TANK BACK INTO SERVICE, THE CONTRACTOR SHALL DISINFECT THE TANK IN ACCORDANCE WITH AMERICAN WATER WORKS ASSOCIATION (AWWA) C652, LATEST EDITION, AND ALL APPLICABLE REGULATORY REQUIREMENTS. DISINFECTION PROCEDURES, BACTERIOLOGICAL TESTING, AND FINAL APPROVAL SHALL BE COORDINATED WITH THE DISTRICT. THE TANK SHALL NOT BE RETURNED TO SERVICE UNTIL ACCEPTABLE BACTERIOLOGICAL RESULTS HAVE BEEN RECEIVED AND WRITTEN AUTHORIZATION IS PROVIDED BY THE DISTRICT. 2.AT THE END OF EACH WORKDAY AND AT ALL TIMES WHEN WORK IS NOT ACTIVELY OCCURRING, THE CONTRACTOR SHALL SECURE THE WATER STORAGE TANK. ALL ACCESS HATCHES, DOORS, MANWAYS, AND OTHER OPENINGS SHALL BE CLOSED, LOCKED, AND SECURED TO PREVENT UNAUTHORIZED ACCESS AND ENSURE PUBLIC SAFETY. 3.FOLLOWING DRAINING OF THE WATER STORAGE TANK, THE CONTRACTOR SHALL CLEAN THE TANK INTERIOR AND REMOVE ANY WATER REMAINING IN THE BOTTOM OF THE TANK. THE CONTRACTOR SHALL ASSUME THAT UP TO TWELVE (12) INCHES OF WATER MAY REMAIN AFTER DRAINING AND SHALL REMOVE AND PROPERLY DISPOSE OF THIS WATER PRIOR TO COMMENCING SUBSEQUENT WORK. 4.ALL ABRASIVE BLAST MEDIA AND REMOVED COATING MATERIALS SHALL BE PROPERLY CONTAINED, HANDLED, AND DISPOSED OF OFF-SITE IN ACCORDANCE WITH AN APPROVED DISPOSAL PLAN AND ALL APPLICABLE REGULATIONS. ABRASIVE MATERIALS SHALL NOT BE REUSED AND SHALL NOT BE PLACED ON THE GROUND OR ANY INTERMEDIATE SURFACE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COORDINATION, SAMPLING, TESTING, TRANSPORTATION, AND DISPOSAL COSTS ASSOCIATED WITH SPENT ABRASIVE BLAST MEDIA AND REMOVED COATING MATERIALS, INCLUDING ANY HAZARDOUS WASTE HANDLING REQUIREMENTS, AS DETERMINED BY FEDERAL AND STATE LAWS AND BY THE DISTRICT. 5.PRIOR TO SURFACE PREPARATION AND RECOATING, PROTECT IN PLACE ALL TANK EQUIPMENT AND APPURTENANCES NOT DESIGNATED TO RECEIVE COATING AND NOT DESIGNATED FOR DEMOLITION AND/OR ABANDONMENT, INCLUDING (BUT NOT LIMITED TO) TANK MIXER, FLOATS/LEVEL CONTROLS, INSTRUMENTATION, SENSORS, WIRING/CONDUIT, AND ANTENNAS. PREVENT ABRASIVE/MEDIA INTRUSION AND COATING OVERSPRAY. REPLACE OR REPAIR ANY ITEMS DAMAGED BY CONTRACTOR OPERATIONS AT NO COST TO THE DISTRICT. 6.CUTTING OF TEMPORARY SHELL OPENINGS (“DOOR SHEETS”) IN THE TANK SHELL FOR CONSTRUCTION ACCESS IS NOT REQUIRED AND SHALL BE PERMITTED ONLY FOR CONTRACTOR CONVENIENCE AND MEANS AND METHODS. ANY PROPOSED SHELL CUTTING SHALL REQUIRE PRIOR WRITTEN APPROVAL BY THE DISTRICT ENGINEER AND SUBMITTAL OF ENGINEER-STAMPED DETAILS AND CALCULATIONS. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR MAINTAINING TANK STRUCTURAL INTEGRITY AND WATERTIGHTNESS. ALL SHELL OPENINGS SHALL BE FULLY RESTORED TO A CONDITION EQUAL TO OR BETTER THAN ORIGINAL, INCLUDING STEEL THICKNESS, WELD QUALITY, SURFACE PREPARATION, AND COATING SYSTEM. ALL COSTS AND RISKS ASSOCIATED WITH SHELL CUTTING AND RESTORATION SHALL BE BORNE BY THE CONTRACTOR. 1 D-1 2 D-1 3 D-1 4 D-1 5 D-1 6 D-1 7 D-1 8 D-1 9 D-1 10 D-1 11 D-1 12 D-1 C-1 3 PLAN 1" = 20' TANK NO. 2 TANK NO. 1 STATELINE TANKS PAVED ACCESS ROAD (MAINTAIN ACCESS) DIRT ROAD (E) BLDG. SOUTH TAHOE PUBLIC UTILITY DISTRICT 1275 MEADOW CREST DRIVE SOUTH LAKE TAHOE, CALIFORNIA 96150 PHONE (530) 544-6474 FAX (530) 541-4319 WWW.STPUD.US OF SHEETS PROJECT CODE REVISIONDATEBY APPROVED DATE SCALE DATE DESIGNED BY DRAWN BY AS-BUILT DRAWN BY AS-BUILT DATE 122026 STATELINE TANKS RECOATING PROJECT SLTNK1/SLTNK2 FEBRUARY 2026 TJ/BG TJ (E) 31" MANWAY (E) 31" MANWAY(E) 36" HATCH (E)INT LADDER (E) RAILING (E) CONCRETE SPLASH BLOCK (E) EXT LADDER (E) 16" OVERFLOW (E) 18" VENT (E) 24" VENT STAGING AREA (E) BASIN NOT APPROVED STAGING AREA (CTC PROPERTY) (E) FH (E) BOLLARDS (E) CONCRETE SPLASH BLOCK (E) 16" OVERFLOW (E) EXT LADDER (E) 36" HATCH (E)INT LADDER (E) RAILING (E) VENT PIPE KEY NOTES STAGING ONLY PERMITTED WITHIN DESIGNATED AREA. MAINTAIN ACCESS TO ALL DOORS, MANHOLES, AND VALVES. 90 FT DIAMETER TANK, 30 FT HEIGHT, 1.25 MG GALLONS DEMOLISH AND REPLACE (E) LADDER FALL PROTECTION SYSTEM W/ NEW 3M DBI-SALA LAD-SAF CABLE VERTICAL SAFETY SYSTEM (BY 3M), OR APPROVED EQUAL. PROTECT (E) COMMUNICATIONS CABLES IN PLACE. PERFORM FULL RECOAT OF THE TANK INTERIOR AND EXTERIOR. FULL EXTERIOR CONTAINMENT TENT PER SPECIFICATIONS REQUIRED. NOTES 1.CONTRACTOR WILL MINIMIZE GROUND AND VEGETATION DISTURBANCE AS MUCH AS POSSIBLE. ANY AREAS OF DISTURBANCE WILL BE WOOD CHIPPED AND/OR REVEGETATED WITH APPROVED SEED PER THE SPECIFICATIONS. 2.CONTRACTOR REQUIRED TO FOLLOW CONFINED SPACE ENTRY PROTOCOL ACCORDING TO OSHA 29 CFR, PART 1910.146. 3.CONTRACTOR REQUIRED TO FOLLOW FALL PROTECTION PROTOCOL PER OSHA 1910.28 4.PROTECT (E) ANTENNAS, CONDUITS, LIGHTS, AND APPURTENANCES MOUNTED TO TANKS IN PLACE. NO COATING (INCLUDING OVERSPRAY) ON LIGHTS NOR ANTENNAS. 5.CLEAR AND GRUB AROUND TANKS AS NEEDED FOR EQUIPMENT ACCESS. PERFORM SITE RESTORATION AND REVEGETATION PER PLANS AND SPECIFICATIONS. 6.INSTALL EROSION CONTROL DEVICES (BMPs) PER SPECIFICATIONS AND TRPA BMP HANDBOOK REQUIREMENTS. 7.PROVIDE TEMPORARY, WATERTIGHT PLUGS OR CAPS IN ALL INLET, OUTLET, OVERFLOW, AND DRAIN PIPING DURING CONSTRUCTION TO PREVENT ENTRY OF DEBRIS, DUST, ABRASIVE MEDIA, AND COATING MATERIAL. MAINTAIN PLUGS IN PLACE UNTIL FINAL CLEANING AND ACCEPTANCE. STEEP SURFACE STEEP SURFACE STEEP SURFACE STEEP SURFACE (E) 24" MANWAY (E) 24" MANWAY (E) VENT PIPE 120 FT DIAMETER TANK, 30 FT HEIGHT, 2.25 MG GALLONS 22.5' 45 ' 9° 15° 6° 10° W12x19 (TYP.) W24x103 (TYP.) W36x160 (TYP.) W14x22 (TYP.) # 1 # 60 # 1 # 36 # 1 # 40 # 1 # 24 TANK #1 RAFTER DETAIL SCALE: NTS TANK #2 RAFTER DETAIL SCALE: NTS 30' APN 029-260-27 (STPUD) APN 029-260-29 (STPUD) APN 029-260-25 (CALIFORNIA TAHOE CONSERVANCY) PROPERTY LINE (TYP.) STRUCTURALLY MODIFY LADDER TO MATCH TANK #2 EXT LADDER. EXTEND LADDER TO WITHIN 12" OF GROUND. MATCH EXISTING RUNG SPACING. MATCH EXISTING MATERIALS. MODIFY LADDER SECURITY GATE TO WORK WITH NEW LADDER LENGTH AND SAFETY CLIMB. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR LADDER AND LADDER SECURITY GATE MODIFICATIONS FOR APPROVAL BY DISTRICT ENGINEER, PRIOR TO COMMENCING WORK. SEE IMAGES 3/D1 AND 7/D1 AND SHEET D2 FOR EXISTING LADDER CONFIGURATIONS. (E) ELECTRICAL (E) ELECTRICAL 1 inch = ft. GRAPHIC SCALE 20 N DEMO EXISTING CATHODIC PROTECTION SYSTEM. REMOVE AND DISPOSE OF ALL WIRES, ANODES, CATHODES, AND APPURTENANCES. SEAL WELD CONDUIT PENETRATIONS WITH 4-INCH CIRCULAR STEEL PLATE OVER THE INSIDE AND OUTSIDE OF THE TANK SHELL PRIOR TO COATING. REMOVE AND DISPOSE OF RECTIFIER AND WIRING BACK TO BREAKER PANEL. (E) 14" INLET/OUTLET PIPE REMOVE EXISTING COATING AND PREPARE AND RECOAT INTERIOR OF PIPING FOR A DISTANCE OF TWO (2) TO THREE (3) PIPE DIAMETERS, MEASURED FROM THE TOP OF PIPE. (E) 14" INLET/ OUTLET PIPE APN 029-260-25 (CALIFORNIA TAHOE CONSERVANCY) STAGING AREA PERFORM SITE GRADING REMOVE AND DISPOSE OF ALL LOOSE, UNSTABLE, OR SLUFFED SOIL AND DEBRIS WITHIN FIVE (5) FEET OF THE TANK SHELL. THIS INCLUDES ANY MATERIAL THAT SLOUGHS, RAVELS, OR FALLS FROM THE ADJACENT HILLSIDE DURING CONSTRUCTION OPERATIONS. REVEGETATE DISTURBED SOILS PER BMP GENERAL NOTES AND SPECIFICATIONS. DEMOLISH AND REPLACE (E) LADDER FALL PROTECTION SYSTEM W/ NEW STAINLESS STEEL 3M DBI-SALA FIXED LADDER SRL ANCHOR (BY 3M), OR APPROVED EQUAL. PROVIDE 3M DBI-SALA SMART LOCK SELF-RETRACTING LIFELINE, OR APPROVED EQUAL. D-1 4 SITE PHOTOS NONE FEBRUARY 2026 SOUTH TAHOE PUBLIC UTILITY DISTRICT 1275 MEADOW CREST DRIVE SOUTH LAKE TAHOE, CALIFORNIA 96150 PHONE (530) 544-6474 FAX (530) 541-4319 WWW.STPUD.US OF SHEETS PROJECT CODE REVISIONDATEBY APPROVED DATE SCALE DATE DESIGNED BY DRAWN BY AS-BUILT DRAWN BY AS-BUILT DATE 122026 STATELINE TANKS RECOATING PROJECT SLTNK1/SLTNK2 FEBRUARY 2026 TJ/BG TJ SITE PHOTO DRIVEWAY ENTRANCE SITE PHOTO DRIVEWAY ENTRANCE SITE PHOTO TANK #1 (FRONT) & OVERFLOW BASIN SITE PHOTO TANK #1 (FRONT) & OVERFLOW BASIN SITE PHOTO TANK #1 (BACKSIDE) SITE PHOTO TANK #1 (BACKSIDE) SITE PHOTO CONTROL BUILDING & TANK #2 (FRONT) SITE PHOTO TANK #2 (FRONT) & STAGING AREA SITE PHOTO TANK #2 (BACKSIDE) SITE PHOTO TANK #2 (BACKSIDE) SITE PHOTO TANK #1 (FRONT) SITE PHOTO TANK #2 (FRONT) TANK #1 (1.25 MG) TANK #1 (1.25 MG)TANK #2 (2.25 MG) OVERFLOW BASIN OVERFLOW PIPE DIRT ROAD (STAGING AREA) REMOVE LOOSE SOILS WITHIN 5FT OF TANK SHELL REMOVE LOOSE SOILS WITHIN 5FT OF TANK SHELL TANK #2 (2.25 MG) STAGING AREA CONTROL BUILDING (KEEP DOORWAY CLEAR) MATCH TANK #1 EXT LADDER TO LOOK LIKE THIS ONE MODIFY THIS LADDER TO MATCH TANK #2 EXT LADDER OVERFLOW BASIN OVERFLOW PIPE OVERFLOW PIPE MANWAY GUARDRAIL GUARDRAIL TANK #2 (2.25 MG) TANK #1 (1.25 MG) MODIFY (E) LADDER TO MATCH TANK #2 EXT LADDER MANWAY FIRE HYDRANT MANWAY STAGING AREA D-2 5 EXTERIOR LADDER PHOTOS NONE FEBRUARY 2026 SOUTH TAHOE PUBLIC UTILITY DISTRICT 1275 MEADOW CREST DRIVE SOUTH LAKE TAHOE, CALIFORNIA 96150 PHONE (530) 544-6474 FAX (530) 541-4319 WWW.STPUD.US OF SHEETS PROJECT CODE REVISIONDATEBY APPROVED DATE SCALE DATE DESIGNED BY DRAWN BY AS-BUILT DRAWN BY AS-BUILT DATE 122026 STATELINE TANKS RECOATING PROJECT SLTNK1/SLTNK2 FEBRUARY 2026 TJ/BG TJ SITE PHOTO TANK #1 LADDER SITE PHOTO TANK #1 LADDER SITE PHOTO TANK #1 LADDER SITE PHOTO TANK #1 LADDER SITE PHOTO TANK #1 LADDER SITE PHOTO TANK #2 LADDER SITE PHOTO TANK #2 LADDER SITE PHOTO TANK #2 LADDER SITE PHOTO TANK #2 LADDER SITE PHOTO TANK #2 LADDER SITE PHOTO TANK #1 LADDER SITE PHOTO TANK #2 LADDER SITE PHOTO TANK #2 LADDER SITE PHOTO TANK #2 LADDER SITE PHOTO TANK #2 LADDER SITE PHOTO TANK #2 LADDER SD-1 6 STANDARD DETAILS NONE VEGETATION PROTECTION FENCING1 SD-1 NO SCALE INCORRECT 48" TALL METAL FENCE POSTS (TYP) DR I P L I N E CORRECT SECTION1 - WOOD 2x. MAINTAIN 3" SPACING MIN. WOOD 2x 12' MINIMUM TALL NOTE: 1)PLACE FENCING SUCH THAT STORM RUNOFF CANNOT PASS UNDER OR AROUND. BURY TOE OF FILTER FABRIC IN 6"x6" TRENCH ON UPHILL SIDE STAKES @ 6' OC W/WELDED WIRE FABRIC. DRAPE FILTER FABRIC OVER FENCE AND TIE WITH TIE WIRES. FENCE IN NATIVE SOIL KEY IN TOE OF FABRIC STAKE STAKE FILTER FABRIC FILTER FABRIC WRAP FABRIC UNDER 1"X LUMBER AND RAMSET TO AC FENCE IN PAVEMENT SECTION 6" 6" FILTER FABRIC FENCE2 SD-1 NO SCALE SOUTH TAHOE PUBLIC UTILITY DISTRICT 1275 MEADOW CREST DRIVE SOUTH LAKE TAHOE, CALIFORNIA 96150 PHONE (530) 544-6474 FAX (530) 541-4319 WWW.STPUD.US OF SHEETS PROJECT CODE REVISIONDATEBY APPROVED DATE SCALE DATE DESIGNED BY DRAWN BY AS-BUILT DRAWN BY AS-BUILT DATE 122026 STATELINE TANKS RECOATING PROJECT SLTNK1/SLTNK2 FEBRUARY 2026 TJ/BG TJ NOTE: 1)SEDIMENT CONTROL BARRIERS USED ON SLOPES, AS CHECK DAMS OR AS SEDIMENT TRAPS SHALL BE BIO-WATTLES AS DISTRIBUTED BY BON-TERRA AMERICA INC. OR APPROVED EQUAL AND INSTALLED AS RECOMMENDED BY THE MANUFACTURE. 1"X1"X24" OR 1"X1"X36" WOODEN STAKES PLACED AT 2' TO 4' ON CENTER DEPENDING ON SLOPE AND SOIL CONDITIONS ANCHOR TRENCH 4" DEEP 12" BIO-WATTLE COIR LOG PLACEMENT3 SD-1 ANCHORING DETAIL SOUTH TAHOE PUBLIC UTILITY DISTRICT 1275 MEADOW CREST DRIVE SOUTH LAKE TAHOE, CALIFORNIA 96150 PHONE (530) 544-6474 FAX (530) 541-4319 WWW.STPUD.US OF SHEETS PROJECT CODE REVISIONDATEBY APPROVED DATE SCALE DATE DESIGNED BY DRAWN BY AS-BUILT DRAWN BY AS-BUILT DATE AS SHOWN 1/30/2026 TDH RJA CP-1 7 SLTNK1/SLTNK2 2026 STATELINE TANKS RECOATING PROJECT STATELINE TANK #1 CATHODIC PROTECTION (PLAN & SECTIONS) 12 ” ” ” SOUTH TAHOE PUBLIC UTILITY DISTRICT 1275 MEADOW CREST DRIVE SOUTH LAKE TAHOE, CALIFORNIA 96150 PHONE (530) 544-6474 FAX (530) 541-4319 WWW.STPUD.US OF SHEETS PROJECT CODE REVISIONDATEBY APPROVED DATE SCALE DATE DESIGNED BY DRAWN BY AS-BUILT DRAWN BY AS-BUILT DATE AS SHOWN 1/30/2026 TDH RJA CP-2 82026 STATELINE TANKS RECOATING PROJECT STATELINE TANK #1 CATHODIC PROTECTION (DETAILS 1)SLTNK1/SLTNK2 12 ” ” ” SOUTH TAHOE PUBLIC UTILITY DISTRICT 1275 MEADOW CREST DRIVE SOUTH LAKE TAHOE, CALIFORNIA 96150 PHONE (530) 544-6474 FAX (530) 541-4319 WWW.STPUD.US OF SHEETS PROJECT CODE REVISIONDATEBY APPROVED DATE SCALE DATE DESIGNED BY DRAWN BY AS-BUILT DRAWN BY AS-BUILT DATE AS SHOWN 1/30/2026 TDH RJA CP-3 9 SLTNK1/SLTNK2STATELINE TANK #1 CATHODIC PROTECTION (DETAILS 2) 2026 STATELINE TANKS RECOATING PROJECT 12 SOUTH TAHOE PUBLIC UTILITY DISTRICT 1275 MEADOW CREST DRIVE SOUTH LAKE TAHOE, CALIFORNIA 96150 PHONE (530) 544-6474 FAX (530) 541-4319 WWW.STPUD.US OF SHEETS PROJECT CODE REVISIONDATEBY APPROVED DATE SCALE DATE DESIGNED BY DRAWN BY AS-BUILT DRAWN BY AS-BUILT DATE AS SHOWN 2/2/2026 TDH WH CP-4 12 SLTNK1/SLTNK2STATELINE TANK #2 CATHODIC PROTECTION (PLAN & PROFILE) 2026 STATELINE TANKS RECOATING PROJECT 10 SOUTH TAHOE PUBLIC UTILITY DISTRICT 1275 MEADOW CREST DRIVE SOUTH LAKE TAHOE, CALIFORNIA 96150 PHONE (530) 544-6474 FAX (530) 541-4319 WWW.STPUD.US OF SHEETS PROJECT CODE REVISIONDATEBY APPROVED DATE SCALE DATE DESIGNED BY DRAWN BY AS-BUILT DRAWN BY AS-BUILT DATE AS SHOWN 2/2/2026 TDH WH CP-5 11 12 STATELINE TANK #2 CATHODIC PROTECTION (DETAILS 1) 2026 STATELINE TANKS RECOATING PROJECT SLTNK1/SLTNK2 SOUTH TAHOE PUBLIC UTILITY DISTRICT 1275 MEADOW CREST DRIVE SOUTH LAKE TAHOE, CALIFORNIA 96150 PHONE (530) 544-6474 FAX (530) 541-4319 WWW.STPUD.US OF SHEETS PROJECT CODE REVISIONDATEBY APPROVED DATE SCALE DATE DESIGNED BY DRAWN BY AS-BUILT DRAWN BY AS-BUILT DATE AS SHOWN 2/2/2026 TDH WH CP-6 12 12 SLTNK1/SLTNK2STATELINE TANK #2 CATHODIC PROTECTION (DETAILS 2) 2026 STATELINE TANKS RECOATING PROJECT