Loading...
HomeMy WebLinkAboutSM20-SM6South Tahoe Public Utility District      Page P-1 Number of sections 1 Total length of sections 213.57 ft Total length of inspected sections 213.57 ft Total length of not inspected sections 0.00 ft Total abandoned inspections 0 Number of section inspection photos 14 Number of section inspection videos 0 Number of section inspection scans 1 Number of section inclination measurements 0 Pipe Segment Reference SM20-SM6 Upstream MH SM20 City SLT Downstream MH SM6 Street Christie Dr Profile Circular 6inch Total Length 213.6 Material Asbestos Cement Distance PACP Code Observation 1 0.0 AMH Manhole 2 0.0 MWL Water Level, 10% of the vertical dimension 3 0.0 SRI Surface Roughness Increased from 9 o'clock to 3 o'clock, within 8 inch 4 2.8 SAV Surface Aggregate Visible from 4 o'clock to 8 o'clock, within 8 inch 5 5.3 JSL Joint Separated Large 6 5.6 DAGS Deposits Attached Grease, 5% of cross sectional area at 4 o'clock, within 8 inch 7 7.5 DAGS Deposits Attached Grease, 5% of cross sectional area at 8 o'clock, within 8 inch 8 7.5 MWM Water Mark, 50% of the vertical dimension 9 8.0 DAGS Deposits Attached Grease, 5% of cross sectional area at 4 o'clock, within 8 inch 10 18.2 DAGS Deposits Attached Grease, 5% of cross sectional area at 4 o'clock, within 8 inch 11 18.5 RFJ Roots Fine Joint at 12 o'clock, within 8 inch 12 19.2 HSV Hole Soil Visible at 12 o'clock, within 8 inch 13 45.9 DAGS Deposits Attached Grease, 5% of cross sectional area at 8 o'clock, within 8 inch 14 91.0 RFJ Roots Fine Joint from 9 o'clock to 3 o'clock, within 8 inch 15 154.5 DAGS Deposits Attached Grease, 5% of cross sectional area at 3 o'clock, within 8 inch 16 158.8 DAGS Deposits Attached Grease, 5% of cross sectional area at 9 o'clock, within 8 inch 17 176.0 SSS Surface Spalling at 11 o'clock, within 8 inch 18 189.1 RFJ Roots Fine Joint from 9 o'clock to 3 o'clock, within 8 inch 19 208.6 RFJ Roots Fine Joint from 8 o'clock to 4 o'clock, within 8 inch 20 212.4 SAV Surface Aggregate Visible from 4 o'clock to 8 o'clock, within 8 inch 21 212.4 SRI Surface Roughness Increased from 9 o'clock to 3 o'clock, within 8 inch 22 213.6 AMH Manhole Section Summary 1/29/2018 Project WinCanVX Master Server South Tahoe Public Utility District      Inspection report Date: Work Order:Pipe Segment Ref.:Weather: Surveyed By: Certificate Number: Year laid: Pre-cleaning: Pipe Joint Length:Direction: Total Length: Length Surveyed: WinCanVX Master Server // Page: 1 City:SLT Drainage Area:K-25 Upstream MH:SM20 Street:Christie Dr Media Label: Up Rim to Invert: Location Code: Flow Control: Downstream MH:SM6 Location Details: Sheet Number: Down Rim to Invert: Pipe shape:Circular Sewer Use: Total gallons used:0.0 Pipe size:6 "Sewer Category:SEC Joints passed:0 Pipe material:Asbestos Cement Purpose: Joints failed:0 Lining Method: Owner: Additional Info:Reviewer ESS T-1208-7921 1:1264 Distance Code Observation Counter Photo Grade 0.0 AMH Manhole / SM20 0.0 MWL Water Level, 10% of the vertical dimension 0.0 SRI Surface Roughness Increased from 9 o'clock to 3 o'clock, within 8 inch 0:00:00 d2c185fd-6 f28-41ff-b1 7d-88baac S1 2.8 SAV Surface Aggregate Visible from 4 o'clock to 8 o'clock, within 8 inch 0:00:05. 54c24307- 9e7a-45fb- 81b4-bb94 5.3 JSL Joint Separated Large 0:00:10. 25a1ae47- 112f-451f- a1cb-cd67f S2 5.6 DAGS Deposits Attached Grease, 5% of cross sectional area at 4 o'clock, within 8 inch 0:00:11. 134ef98a-f 085-45e1- bb80-acab M2 7.5 DAGS Deposits Attached Grease, 5% of cross sectional area at 8 o'clock, within 8 inch 0:00:15. ee1dc6db- 2a50-4902 -9671-d28 M2 7.5 MWM Water Mark, 50% of the vertical dimension 0:00:15. 1c2c3f93-0 54f-4cab-8 b16-ddaa3 M4 8.0 DAGS Deposits Attached Grease, 5% of cross sectional area at 4 o'clock, within 8 inch 0:00:16. e75146d6- 45da-455c -88e2-b1e 18.2 DAGS Deposits Attached Grease, 5% of cross sectional area at 4 o'clock, within 8 inch 0:00:37 e4e3273d- 137d-4ce8 -975e-a25 M2 18.5 RFJ Roots Fine Joint at 12 o'clock, within 8 inch 0:00:37. 42a13060- 3c54-41f0- 937c-4fad5 M1 19.2 HSV Hole Soil Visible at 12 o'clock, within 8 inch 0:00:39 S5 45.9 DAGS Deposits Attached Grease, 5% of cross sectional area at 8 o'clock, within 8 inch 0:01:33. 4283b6bb- e36b-4894 -af79-b2d3 M2 91.0 RFJ Roots Fine Joint from 9 o'clock to 3 o'clock, within 8 inch 0:03:05 d2102909- 907e-478d -9d37-fc5f M1 154.5 DAGS Deposits Attached Grease, 5% of cross sectional area at 3 o'clock, within 8 inch 0:05:14 7f0a6fc7-7 b72-4590- 82da-77c2 M2 158.8 DAGS Deposits Attached Grease, 5% of cross sectional area at 9 o'clock, within 8 inch 0:05:22. M2 3/12/2019 JPaul U-0519070304953 SM20-SM6 No Pre-Cleaning Downstream 213.6 ' 213.6 ' SM20 South Tahoe Public Utility District      Inspection report Date: Work Order:Pipe Segment Ref.:Weather: Surveyed By: Certificate Number: Year laid: Pre-cleaning: Pipe Joint Length:Direction: Total Length: Length Surveyed: WinCanVX Master Server // Page: 2 1:1264 Distance Code Observation Counter Photo Grade 176.0 SSS Surface Spalling at 11 o'clock, within 8 inch 0:05:57. S2 189.1 RFJ Roots Fine Joint from 9 o'clock to 3 o'clock, within 8 inch 0:06:24. 64aa0db9- 29b7-410f- 8373-9551 M1 208.6 RFJ Roots Fine Joint from 8 o'clock to 4 o'clock, within 8 inch 0:07:04 235d185b- 1087-4ab1 -88de-940 M1 212.4 SAV Surface Aggregate Visible from 4 o'clock to 8 o'clock, within 8 inch 0:07:11. S3 212.4 SRI Surface Roughness Increased from 9 o'clock to 3 o'clock, within 8 inch 0:07:11. S1 213.6 AMH Manhole / SM6 3/12/2019 JPaul U-0519070304953 SM20-SM6 No Pre-Cleaning Downstream 213.6 ' 213.6 ' QSR QMR SPR MPR OPR SPRI MPRI OPRI 513Z 4129 430.0 26.0 3.0 1.9 2.9456.0 QOR 5141 SM6